/*
Please refer to readme.html for full Instructions

Text[...]=[Range,The desired temperature drop of the fluid measured as the difference between incoming and outgoing fluid temperatures.]

Style[...]=[TitleColor"FFFFFF",TextColor"3366CC",TitleBgColor"3366CC",TextBgColor"FFFFFF",TitleBgImag,TextBgImag,TitleTextAlign,TextTextAlign, TitleFontFace, TextFontFace, TipPosition"right", StickyStyle, TitleFontSize, TextFontSize, Width, Height, BorderSize, PadTextArea, CoordinateX , CoordinateY, TransitionNumber, TransitionDuration, TransparencyLevel ,ShadowType, ShadowColor]
*/

var FiltersEnabled = 1 // if your not going to use transitions or filters in any of the tips set this to 0

Text[0]=["Conformance","Standard TX2-TX25 chiller barrels are UL listed for 225 psi tube side and 225 psi shell side working pressures.  TXB30/TXC30 - TXC500 units are constructed to ASME standards for 225 psi tube side. TXB and TXC units are rated for 150 psi shell side working pressures.  Each unit is tested before shipment and ratings are developed through extensive laboratory testing and computer modeling.<br><br>Nominal Tonnage Rating Basis<br><br>Nominal ratings are based on ARI standard 480, specific conditions being:<br> 1 ton=12,000Btu/hr&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;100&deg;F.liquid entering TXV<br> 54&deg;F.inlet water&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;7&deg; superheat<br> 44&deg;F.outlet water&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;35&deg;F R22 Saturated Suction<br>0.0001ft&#178;hr&deg;F/Btu additive fouling factor"]
Text[1]=["Limitations","1. For cooling water applications a minimum evaporating temperature of 32&deg;F. should be maintained in the evaporator to prevent freezing.<br><br>2. Maximum water entering temperature of 70&deg;F.<br><br>3. Minimum outgoing water temperature of 36&deg;F.<br><br>4. Minimum approach 5&deg; (for approaches 6&deg; or less, system should be designed to insure proper oil return).<br><br>Note: For brine, low temperature and special design applications, please consult factory for complete technical assistance. Do not exceed maximum stated flowrate."]
Text[2]=["Range","The desired temperature drop of the fluid measured as the difference between incoming and outgoing fluid temperatures."]
Text[3]=["Approach","The desired temperature difference between outgoing fluid and the refrigerant"]
Text[4]=["Pressure Drop","Acceptable level of fluid system pressure drop through the chiller barrel at computed gallons per minute (gpm) flow rate."]


Style[0]=["white","3366CC","#969696","#ffffff","","","","","","","","","","",300,"",2,4,10,10,,1,0,"",""]
Style[1]=["white","black","#000099","#E8E8FF","","","","","","","center","","","",200,"",2,2,10,10,"","","","",""]
Style[2]=["white","black","#000099","#E8E8FF","","","","","","","left","","","",200,"",2,2,10,10,"","","","",""]
Style[3]=["white","black","#000099","#E8E8FF","","","","","","","float","","","",200,"",2,2,10,10,"","","","",""]
Style[4]=["white","black","#000099","#E8E8FF","","","","","","","fixed","","","",200,"",2,2,1,1,"","","","",""]
Style[5]=["white","black","#000099","#E8E8FF","","","","","","","","sticky","","",200,"",2,2,10,10,"","","","",""]
Style[6]=["white","black","#000099","#E8E8FF","","","","","","","","keep","","",200,"",2,2,10,10,"","","","",""]
Style[7]=["white","black","#000099","#E8E8FF","","","","","","","","","","",200,"",2,2,40,10,"","","","",""]
Style[8]=["white","black","#000099","#E8E8FF","","","","","","","","","","",200,"",2,2,10,50,"","","","",""]
Style[9]=["white","black","#000099","#E8E8FF","","","","","","","","","","",200,"",2,2,10,10,51,0.5,75,"simple","gray"]
Style[10]=["white","black","black","white","","","right","","Impact","cursive","center","",3,5,200,150,5,20,10,0,50,1,80,"complex","gray"]
Style[11]=["white","black","#000099","#E8E8FF","","","","","","","","","","",200,"",2,2,10,10,51,0.5,45,"simple","gray"]
Style[12]=["white","black","#000099","#E8E8FF","","","","","","","","","","",200,"",2,2,10,10,"","","","",""]

applyCssFilter()

